top of page

technical data

Test
Standard
ASTM C-666 (b)
at least 150 PSI for all 10 panels

Test Description: Center brick is extracted from 5 precast panels. Another set of 5 precast panels undergo 300 cycles of freeze/thaw and then the center brick is extracted. 

Imperial Bricks Angle.jpg

PCI Freeze/thaw pullout

King Klinker thin brick exceeded the freeze/thaw tests by at least 27%.  Freeze/thaw cycles have little effect on King Klinker thin brick. King Klinker passed for all clay body colors. 

Please contact us for PCI certification letter. 

Red Clay Body

Brown Clay Body

White Clay Body

Test
Standard
ASTM C1088
Less than 5%

Test Description: Brick is placed in cold water for 24 hours and boiling water for 5 hours. 

water absorption

King Klinker thin brick has a water absorption of ~3%, just enough water absorption for perfect bonding yet not too much for maximum integrity of the clay body. 

Red Clay Body

Brown Clay Body

White Clay Body

Water%20Absorption%20graphic%20ONLY%20BR
Test
Standard
ASTM C1088
None
Test
Standard
ASTM C1088
None
Cool Brick Photo.png

Efflorescense

King Klinker thin brick has no chalky white efflorescense usually caused by impurities in the clay.

Red Clay Body

Brown Clay Body

White Clay Body

Test
Dimensions of L, W or H
TBX Standard
ASTM 216
3" and under
+/- 1/16"
Over 3" to 4"
+/- 3/32"
Over 4" to 6"
+/- 1/8"
Over 6" to 8"
+/- 5/32"
Over 8" to 12"
+/- 7/32"
Over 12" to 16"
+/- 9/32"
Test
Dimensions of L, W or H
TBX Standard
ASTM 216
3" and under
+/- 1/16"
Over 3" to 4"
+/- 3/32"
Over 4" to 6"
+/- 1/8"
Over 6" to 8"
+/- 5/32"
Over 8" to 12"
+/- 7/32"
Over 12" to 16"
+/- 9/32"
Test
Dimensions of L, W or H
PCI Standard
PCI
up to 8"
+0" / - 1/16"
up to 12"
+ 0" / - 3/32"
Test
Dimensions of L, W or H
PCI Standard
PCI
up to 8"
+0" / - 1/16"
up to 12"
+ 0" / - 3/32"

sIZE

King Klinker thin brick meet TBX tolerance for all sizes.

Modular and Norman meet PCI dimensional standards for precast projects.

Architect%20with%20Imperial%20Brick%20CM
Test
Dimensions of L, W or H
TBX Standard
ASTM 216
8" and under
1/16"
Over 8" to 12"
3/32"
Over 12" to 16"
1/8"

Test Description: Bricks tend to bow the longer the dimension.

Test
Dimensions of L, W or H
PCI Standard
PCI
up to 12"
1/16"

Test Description: Important for Precast as bricks get stepped on before pour.

Test
Dimensions of L, W or H
TBX Standard
ASTM 216
8" and under
1/16"
Over 8" to 12"
3/32"
Over 12" to 16"
1/8"
Test
Dimensions of L, W or H
PCI Standard
PCI
up to 12"
1/16"
IMG_2996 (1).jpg

WArpage

All King Klinker thin brick sizes meets the warpage standard of TBX.

Safety 

Report

Test
Standard
PN-EN ISO 10545-13
Hydrochloric acid 3% Citric acid 10% Potassium hydroxide 3%
Test
Standard
PN-EN ISO 10545-13
Hydrochloric acid 3% Citric acid 10% Potassium hydroxide 3%

chemical resistance

King Klinker thin brick is not affected by acidic cleaning agents.

Cleaning.jpg
bottom of page